Installation
Apollo SL50 / SL60 Installation Manual
19
Apollo
SL50/60
Moving Map
Display
RxD
Ground
Ground
TxD1
RxD1
Connect shields to mounting
frame with ground lead
Shielded
Cable
Apollo
SL40 Comm
RxD
5
4
3
Shielded
Cable
Notes:
2. Connect cable shields to the rear of the mounting frame with pigtails < 1.25 inches.
1. Use shielded cable for all RS-232 interface connections.
3. Connect shields to chassis ground at both ends of each shielded cable.
10
11
37 Pin Connector
Figure 9 RS-232 Serial Interface Connections
Commentaires sur ces manuels